1. HANDLING PRECAUTION
1-1. MOUNTING METHOD
The panel of the LCD module consists of two thin glass plates with polarizes which
easily get damaged since the module is fixed by utilizing fitting holes in the
printed circuit board. Extreme care should be taken when handling the LCD modules.
1-2. CAUTION OF LCD HANDLING & CLEANING
When cleaning the display surface. Use soft cloth with solvent (recommended below)
and wipe lightly.
-Isopropyl alcohol
-Ethyl alcohol
-Tri chlorotri fluoroethane
Do not wipe the display surface with dry or hard materials that will damage the
polarizes surface.
Do not use the following solvent:
-Water
-Ketones
-Aromatics
1-3.CAUTION AGAINST STATIC CHARGE
The LCD modules use COMS LSI drivers. So we recommend that you connect any unused
input terminal to Vdd or Vss, do not input any signals before power is turned on and
ground your body. work/assembly table. And assembly equipment to protect against
static electricity.
1-4.PACKAGING
-Modules use LCD elements, and must be treated as such avoid intense shock and
falls from a height
-To prevent modules from degradation, do not operate or store them exposed
directly to sunshine or high temperature/humidity.
1-5.CAUTION FOR OPERATION
-It is indispensable to drive LCM within the specified voltage limit since the
higher voltage than the limit shortens LCM life.
-Response time will be extremely delayed at lower temperature than the operating
temperature range and on the other hand at higher temperature LCD show dark color in
them.
However those phenomena do not mean malfunction or out of order with LCD, which
will come back in the specified operating temperature range.
-If the display area is pushed hard during operation. Some font will be abnormally
displayed but it resumes normal condition after turning off once.
-A slight dew depositing on terminals is a cause for Electro-chemical reaction
resulting in terminal open circuit.
Under the maximum operating temperature, 50%RH or less is required
1-6 STORAGE
In the case of storing for a long period of time (for instance, for years) for the
purpose or replacement use. the following ways are recommended
-Storage in a polyethylene bag with the opening sealed so as not to enter fresh
air outside in it, and with no desiccant.
-Placing in a dark place where neither exposure to direct sunlight nor light is,
keeping temperature in the specified storage temperature range.
-Storing with no touch on polarizes surface by the anythingelse.
(it is recommended to store them as they have been contained in the inner container
at the time of delivery from us.
1-7.SAFETY
-It is recommendable to crash damaged or unnecessary LCD into pieces and wash off
liquid crystal by using solvents such as acetone and ethanol, which should be burned
up later.
-When any liquid crystal leaked out of a damaged glass cell comes in contact with
your hands, please wash it off well with soap and water.
2.PRECAUTION FOR USE
2-1.A limit sample should be provided by the both parties on an occasion when the
both parties agree its necessity.
Judgement by a limit sample shall take effect after the limit sample has been
established and confirmed by the both parties.
2-2.On the following occasions, the handling of problem should be decided through
discussion and agreement between representative of the both parties
-When a question is arisen in this specification.
-When a new problem is arisen which is not specified in this specifications.
-When an inspection specification change or operating condition change in customer
is reported to GEM-TECH, and some problem is arisen in this specification due to the
change.
-When a new problem is arisen at the customer's operating set for sample
evaluation in the customer size.
Back